Question 410
Before applying the planned operation “Use redundant uplinks rather than a single-chain design for critical endpoints” at the training center, the administrator must predict its impact. Which prediction is sound?
- One switch tier aggregates downstream access units via ISLs or supported trunks
- First-tier peers act as a redundant upstream anchor for downstream distribution or access switches
- Redundant topology design removes a single parent chassis from the data-plane dependency chain
- Supported tiered MCLAG topologies permit multi-layer redundancy with active member links
Explanation
Correct Answer
C:For the stated requirement, the configured operation is meant to prevent an upstream switch failure disconnecting every switch below it. The most relevant validation is to perform a parent-switch outage test and observe remaining access-layer connectivity for the equipment at the training center.
Incorrect Answers
A:This outcome would be relevant to “Deploy a two-tier FortiSwitch hierarchy” at the training center, not the task “Use redundant uplinks rather than a single-chain design for critical endpoints”; the other task is to separate distribution and access functions while keeping central FortiLink management. The action “Use redundant uplinks rather than a single-chain design for critical endpoints” targets a different result: redundant topology design removes a single parent chassis from the data-plane dependency chain; the proposed alternative would instead be checked by verify which tier holds the FortiGate uplink and which links serve access switches.
B:That behavior applies when engineers “Provide first-tier MCLAG before downstream redundancy”; the different operation “Use redundant uplinks rather than a single-chain design for critical endpoints” is intended to prevent an upstream switch failure disconnecting every switch below it. That different feature is verified by monitor first-tier peer synchronization and FortiLink reachability after failover; for “Use redundant uplinks rather than a single-chain design for critical endpoints” on a recently upgraded FortiSwitch, the relevant evidence is to perform a parent-switch outage test and observe remaining access-layer connectivity.
D:That behavior applies when engineers “Design a three-tier MCLAG hierarchy”; the different operation “Use redundant uplinks rather than a single-chain design for critical endpoints” is intended to prevent an upstream switch failure disconnecting every switch below it. That different feature is verified by audit per-tier peer groups and the full three-layer physical uplink map; for “Use redundant uplinks rather than a single-chain design for critical endpoints” on a recently upgraded FortiSwitch, the relevant evidence is to perform a parent-switch outage test and observe remaining access-layer connectivity.
Question 411
The accepted design for the lab requires the ability to provide different clients with independent firewall rules and routing contexts. Which switch feature is the closest fit?
- Share one FortiSwitch port between VDOM VLANs
- Create an auditable tenant interface inventory
- Use separate FortiGate VDOMs for tenant policy boundaries
- Use shared-port supported MAC learning limits
Explanation
Correct Answer
C:The deciding detail is that each VDOM operates as a logical firewall domain while managed switching can be assigned to serve those domains. This distinction is material to the lab, where the stated goal is to provide different clients with independent firewall rules and routing contexts.
Incorrect Answers
A:Compared with the requested “Use separate FortiGate VDOMs for tenant policy boundaries” at the lab, this would carry several tenant-specific tagged networks over a shared physical uplink instead: a shared port can transport VLAN interfaces that belong to different FortiGate VDOMs. At the lab, the operational proof would instead be to inspect per-tenant VDOM routing and firewall policy tables, whereas “Share one FortiSwitch port between VDOM VLANs” is validated by a different test: verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership.
B:For the lab, “Create an auditable tenant interface inventory” is a different type of control from “Use separate FortiGate VDOMs for tenant policy boundaries”: explicit mapping of VDOM, VLAN and switch port establishes configuration ownership. Unlike the requested feature, that setting addresses the need to avoid accidental reassignments of another client's access ports, not the objective to provide different clients with independent firewall rules and routing contexts.
D:Compared with the requested “Use separate FortiGate VDOMs for tenant policy boundaries” at the lab, this would limit learned addresses where a tenant is using a shared switch port instead: supported port or VLAN MAC limits constrain entries in hardware even with multiple tenant domains. At the lab, the operational proof would instead be to inspect per-tenant VDOM routing and firewall policy tables, whereas “Use shared-port supported MAC learning limits” is validated by a different test: inspect MAC-limit status and per-tenant VLAN membership for the port.
Question 412
Before applying the planned operation “Use separate FortiGate VDOMs for tenant policy boundaries” at the staging rack, the administrator must predict its impact. Which prediction is sound?
- Port security can be supported on shared VDOM ports, subject to exact feature constraints
- Virtual-domain routing contexts can have distinct defaults and destination networks on the same FortiGate
- PVLANs partition L2 communication within a VLAN, whereas VDOMs separate FortiGate policy and route contexts
- FortiLink management association and tenant-facing VDOM interfaces serve different roles in the deployment
- Each VDOM operates as a logical firewall domain while managed switching can be assigned to serve those domains
Explanation
Correct Answer
E:The relevant mechanism is: the configured operation is meant to provide different clients with independent firewall rules and routing contexts. The most relevant validation is to inspect per-tenant VDOM routing and firewall policy tables for the equipment at the staging rack.
Incorrect Answers
A:That behavior applies when engineers “Apply supported port-security policy to a shared port”; the different operation “Use separate FortiGate VDOMs for tenant policy boundaries” is intended to provide different clients with independent firewall rules and routing contexts. That different feature is verified by check the access/authentication policy and the VLANs associated with permitted sessions; for “Use separate FortiGate VDOMs for tenant policy boundaries” on a switch linked to a FortiGate running FortiOS 7.6, the relevant evidence is to inspect per-tenant VDOM routing and firewall policy tables.
B:That behavior applies when engineers “Use per-tenant route tables through VDOM separation”; the different operation “Use separate FortiGate VDOMs for tenant policy boundaries” is intended to provide different clients with independent firewall rules and routing contexts. That different feature is verified by compare route entries in each VDOM before diagnosing tenant reachability; for “Use separate FortiGate VDOMs for tenant policy boundaries” on a switch linked to a FortiGate running FortiOS 7.6, the relevant evidence is to inspect per-tenant VDOM routing and firewall policy tables.
C:That behavior applies when engineers “Avoid confusing private VLANs with FortiGate VDOMs”; the different operation “Use separate FortiGate VDOMs for tenant policy boundaries” is intended to provide different clients with independent firewall rules and routing contexts. That different feature is verified by test whether the proposed design needs host-to-host restriction or independent policy/routing tables; for “Use separate FortiGate VDOMs for tenant policy boundaries” on a switch linked to a FortiGate running FortiOS 7.6, the relevant evidence is to inspect per-tenant VDOM routing and firewall policy tables.
D:This outcome would be relevant to “Keep FortiLink management ownership separate from tenant traffic” at the staging rack, not the task “Use separate FortiGate VDOMs for tenant policy boundaries”; the other task is to prevent tenant data VDOM changes from unintentionally severing switch-controller access. The action “Use separate FortiGate VDOMs for tenant policy boundaries” targets a different result: each VDOM operates as a logical firewall domain while managed switching can be assigned to serve those domains; the proposed alternative would instead be checked by inspect controller reachability and tenant forwarding independently during changes.
Question 413
A post-change review at the research building must validate the implementation of “Use separate FortiGate VDOMs for tenant policy boundaries.” What should the reviewer inspect first?
- Inspect MAC-limit status and per-tenant VLAN membership for the port
- Inspect per-tenant VDOM routing and firewall policy tables
- Compare physical port inventory with configured tenant interface objects
- Verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership
Explanation
Correct Answer
B:This approach fits because each VDOM operates as a logical firewall domain while managed switching can be assigned to serve those domains. Directly measuring that result demonstrates whether the step to provide different clients with independent firewall rules and routing contexts succeeded on a switch serving a high-density endpoint area.
Incorrect Answers
A:The proposed check concerns “Use shared-port supported MAC learning limits” rather than “Use separate FortiGate VDOMs for tenant policy boundaries”: supported port or VLAN MAC limits constrain entries in hardware even with multiple tenant domains. For “Use separate FortiGate VDOMs for tenant policy boundaries” on a switch serving a high-density endpoint area, a better test would be to inspect per-tenant VDOM routing and firewall policy tables, which targets provide different clients with independent firewall rules and routing contexts rather than the alternative diagnostic “Use shared-port supported MAC learning limits”.
C:This check is suited to “Create an auditable tenant interface inventory” when trying to avoid accidental reassignments of another client's access ports, not to verify “Use separate FortiGate VDOMs for tenant policy boundaries” at the research building. Checking “Use separate FortiGate VDOMs for tenant policy boundaries” at the research building requires evidence of its own mechanism: each VDOM operates as a logical firewall domain while managed switching can be assigned to serve those domains; that is not the outcome measured by “Create an auditable tenant interface inventory”.
D:This check is suited to “Share one FortiSwitch port between VDOM VLANs” when trying to carry several tenant-specific tagged networks over a shared physical uplink, not to verify “Use separate FortiGate VDOMs for tenant policy boundaries” at the research building. Checking “Use separate FortiGate VDOMs for tenant policy boundaries” at the research building requires evidence of its own mechanism: each VDOM operates as a logical firewall domain while managed switching can be assigned to serve those domains; that is not the outcome measured by “Share one FortiSwitch port between VDOM VLANs”.
Question 414
A deployment review at the clinic identifies this objective: assign an endpoint-facing physical interface to a single tenant. Which FortiSwitch operation should be selected?
- Use separate FortiGate VDOMs for tenant policy boundaries
- Dedicate a managed switch port to one VDOM
- Map an inter-switch trunk to multiple VDOM VLANs
- Use shared-port supported PoE settings
Explanation
Correct Answer
B:The critical distinction is that port-to-VDOM mapping places that port's associated network into the intended tenant context. The operator can test this claim by the specific check: inspect the switch-controller port assignment and tenant VLAN ownership.
Incorrect Answers
A:Compared with the requested “Dedicate a managed switch port to one VDOM” at the clinic, this would provide different clients with independent firewall rules and routing contexts instead: each VDOM operates as a logical firewall domain while managed switching can be assigned to serve those domains. At the clinic, the operational proof would instead be to inspect the switch-controller port assignment and tenant VLAN ownership, whereas “Use separate FortiGate VDOMs for tenant policy boundaries” is validated by a different test: inspect per-tenant VDOM routing and firewall policy tables.
C:For the clinic, “Map an inter-switch trunk to multiple VDOM VLANs” is a different type of control from “Dedicate a managed switch port to one VDOM”: the trunk transports allowed VLAN IDs while their FortiGate interfaces retain separate VDOM associations. Unlike the requested feature, that setting addresses the need to carry separate customer networks across distribution without collapsing them into one tenant, not the objective to assign an endpoint-facing physical interface to a single tenant.
D:Compared with the requested “Dedicate a managed switch port to one VDOM” at the clinic, this would serve an Ethernet-powered device on a shared physical port where the model supports it instead: selected physical port properties such as PoE may be configured even when VLAN interfaces span VDOMs. At the clinic, the operational proof would instead be to inspect the switch-controller port assignment and tenant VLAN ownership, whereas “Use shared-port supported PoE settings” is validated by a different test: check the exact hardware feature support and effective PoE behavior on that port.
Question 415
During validation of a remote FortiSwitch installation at the data hall, the team asks what the change “Dedicate a managed switch port to one VDOM” actually does. Which outcome is correct?
- Firewall policy processing follows the VDOM context of the VLAN/interface that receives routed traffic
- Port-to-VDOM mapping places that port's associated network into the intended tenant context
- Supported egress CoS queue policies can apply on a shared physical interface
- FortiSwitch multi-tenancy has feature-specific restrictions; a model/version check is needed before rollout
Explanation
Correct Answer
B:That setting is appropriate here because the configured operation is meant to assign an endpoint-facing physical interface to a single tenant. The most relevant validation is to inspect the switch-controller port assignment and tenant VLAN ownership for the equipment at the data hall.
Incorrect Answers
A:That behavior applies when engineers “Apply tenant-specific firewall policies in each VDOM”; the different operation “Dedicate a managed switch port to one VDOM” is intended to assign an endpoint-facing physical interface to a single tenant. That different feature is verified by examine the policy lookup inside the affected tenant VDOM; for “Dedicate a managed switch port to one VDOM” on a remote FortiSwitch installation, the relevant evidence is to inspect the switch-controller port assignment and tenant VLAN ownership.
C:That behavior applies when engineers “Use QoS egress policy on shared VDOM switch ports”; the different operation “Dedicate a managed switch port to one VDOM” is intended to assign an endpoint-facing physical interface to a single tenant. That different feature is verified by check transmitted queue counters and supported shared-port configuration; for “Dedicate a managed switch port to one VDOM” on a remote FortiSwitch installation, the relevant evidence is to inspect the switch-controller port assignment and tenant VLAN ownership.
D:This outcome would be relevant to “Review shared-port feature limitations before deployment” at the data hall, not the task “Dedicate a managed switch port to one VDOM”; the other task is to avoid assuming every switching feature is available across all VDOM-sharing configurations. The action “Dedicate a managed switch port to one VDOM” targets a different result: port-to-VDOM mapping places that port's associated network into the intended tenant context; the proposed alternative would instead be checked by validate the planned shared-port feature against the FortiLink Guide and platform matrix.
Question 416
The work order to assign an endpoint-facing physical interface to a single tenant is marked complete on an endpoint-facing FortiSwitch port. Which observation most directly tests the completed configuration?
- Inspect the switch-controller port assignment and tenant VLAN ownership
- Verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership
- Inspect per-tenant VDOM routing and firewall policy tables
- Check the exact hardware feature support and effective PoE behavior on that port
- Inspect VLAN-to-VDOM ownership and tag preservation over both trunk endpoints
Explanation
Correct Answer
A:This is the precise control because port-to-VDOM mapping places that port's associated network into the intended tenant context. Directly measuring that result demonstrates whether the step to assign an endpoint-facing physical interface to a single tenant succeeded on an endpoint-facing FortiSwitch port.
Incorrect Answers
B:The proposed check concerns “Share one FortiSwitch port between VDOM VLANs” rather than “Dedicate a managed switch port to one VDOM”: a shared port can transport VLAN interfaces that belong to different FortiGate VDOMs. For “Dedicate a managed switch port to one VDOM” on an endpoint-facing FortiSwitch port, a better test would be to inspect the switch-controller port assignment and tenant VLAN ownership, which targets assign an endpoint-facing physical interface to a single tenant rather than the alternative diagnostic “Share one FortiSwitch port between VDOM VLANs”.
C:This check is suited to “Use separate FortiGate VDOMs for tenant policy boundaries” when trying to provide different clients with independent firewall rules and routing contexts, not to verify “Dedicate a managed switch port to one VDOM” at the warehouse. Checking “Dedicate a managed switch port to one VDOM” at the warehouse requires evidence of its own mechanism: port-to-VDOM mapping places that port's associated network into the intended tenant context; that is not the outcome measured by “Use separate FortiGate VDOMs for tenant policy boundaries”.
D:The proposed check concerns “Use shared-port supported PoE settings” rather than “Dedicate a managed switch port to one VDOM”: selected physical port properties such as PoE may be configured even when VLAN interfaces span VDOMs. For “Dedicate a managed switch port to one VDOM” on an endpoint-facing FortiSwitch port, a better test would be to inspect the switch-controller port assignment and tenant VLAN ownership, which targets assign an endpoint-facing physical interface to a single tenant rather than the alternative diagnostic “Use shared-port supported PoE settings”.
E:This check is suited to “Map an inter-switch trunk to multiple VDOM VLANs” when trying to carry separate customer networks across distribution without collapsing them into one tenant, not to verify “Dedicate a managed switch port to one VDOM” at the warehouse. Checking “Dedicate a managed switch port to one VDOM” at the warehouse requires evidence of its own mechanism: port-to-VDOM mapping places that port's associated network into the intended tenant context; that is not the outcome measured by “Map an inter-switch trunk to multiple VDOM VLANs”.
Question 417
On a recently upgraded FortiSwitch in the headquarters, the next task is to carry several tenant-specific tagged networks over a shared physical uplink. What is the appropriate configuration decision?
- Share one FortiSwitch port between VDOM VLANs
- Apply supported port-security policy to a shared port
- Keep FortiLink management ownership separate from tenant traffic
- Apply tenant-specific firewall policies in each VDOM
Explanation
Correct Answer
A:The implementation works because a shared port can transport VLAN interfaces that belong to different FortiGate VDOMs. This distinction is material to the headquarters, where the stated goal is to carry several tenant-specific tagged networks over a shared physical uplink.
Incorrect Answers
B:Compared with the requested “Share one FortiSwitch port between VDOM VLANs” at the headquarters, this would secure access to shared infrastructure without assuming one VDOM owns every VLAN instead: port security can be supported on shared VDOM ports, subject to exact feature constraints. At the headquarters, the operational proof would instead be to verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership, whereas “Apply supported port-security policy to a shared port” is validated by a different test: check the access/authentication policy and the VLANs associated with permitted sessions.
C:For the headquarters, “Keep FortiLink management ownership separate from tenant traffic” is a different type of control from “Share one FortiSwitch port between VDOM VLANs”: FortiLink management association and tenant-facing VDOM interfaces serve different roles in the deployment. Unlike the requested feature, that setting addresses the need to prevent tenant data VDOM changes from unintentionally severing switch-controller access, not the objective to carry several tenant-specific tagged networks over a shared physical uplink.
D:Compared with the requested “Share one FortiSwitch port between VDOM VLANs” at the headquarters, this would prevent one client's security rule changes from altering another client's traffic instead: firewall policy processing follows the VDOM context of the VLAN/interface that receives routed traffic. At the headquarters, the operational proof would instead be to verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership, whereas “Apply tenant-specific firewall policies in each VDOM” is validated by a different test: examine the policy lookup inside the affected tenant VDOM.
Question 418
Before applying the planned operation “Share one FortiSwitch port between VDOM VLANs” at the hospital wing, the administrator must predict its impact. Which prediction is sound?
- The trunk transports allowed VLAN IDs while their FortiGate interfaces retain separate VDOM associations
- Port-to-VDOM mapping places that port's associated network into the intended tenant context
- Supported port or VLAN MAC limits constrain entries in hardware even with multiple tenant domains
- A shared port can transport VLAN interfaces that belong to different FortiGate VDOMs
Explanation
Correct Answer
D:Given the described goal, the configured operation is meant to carry several tenant-specific tagged networks over a shared physical uplink. The most relevant validation is to verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership for the equipment at the hospital wing.
Incorrect Answers
A:That behavior applies when engineers “Map an inter-switch trunk to multiple VDOM VLANs”; the different operation “Share one FortiSwitch port between VDOM VLANs” is intended to carry several tenant-specific tagged networks over a shared physical uplink. That different feature is verified by inspect VLAN-to-VDOM ownership and tag preservation over both trunk endpoints; for “Share one FortiSwitch port between VDOM VLANs” on a FortiLink-managed access switch, the relevant evidence is to verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership.
B:This outcome would be relevant to “Dedicate a managed switch port to one VDOM” at the hospital wing, not the task “Share one FortiSwitch port between VDOM VLANs”; the other task is to assign an endpoint-facing physical interface to a single tenant. The action “Share one FortiSwitch port between VDOM VLANs” targets a different result: a shared port can transport VLAN interfaces that belong to different FortiGate VDOMs; the proposed alternative would instead be checked by inspect the switch-controller port assignment and tenant VLAN ownership.
C:That behavior applies when engineers “Use shared-port supported MAC learning limits”; the different operation “Share one FortiSwitch port between VDOM VLANs” is intended to carry several tenant-specific tagged networks over a shared physical uplink. That different feature is verified by inspect MAC-limit status and per-tenant VLAN membership for the port; for “Share one FortiSwitch port between VDOM VLANs” on a FortiLink-managed access switch, the relevant evidence is to verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership.
Question 419
A technician says “Share one FortiSwitch port between VDOM VLANs” has solved the issue at the training center. Which diagnostic step would substantiate that claim?
- Check the access/authentication policy and the VLANs associated with permitted sessions
- Compare route entries in each VDOM before diagnosing tenant reachability
- Examine the policy lookup inside the affected tenant VDOM
- Inspect controller reachability and tenant forwarding independently during changes
- Verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership
Explanation
Correct Answer
E:The switch behavior that matters is: a shared port can transport VLAN interfaces that belong to different FortiGate VDOMs. Directly measuring that result demonstrates whether the step to carry several tenant-specific tagged networks over a shared physical uplink succeeded on a switch linked to a FortiGate running FortiOS 7.6.
Incorrect Answers
A:The proposed check concerns “Apply supported port-security policy to a shared port” rather than “Share one FortiSwitch port between VDOM VLANs”: port security can be supported on shared VDOM ports, subject to exact feature constraints. For “Share one FortiSwitch port between VDOM VLANs” on a switch linked to a FortiGate running FortiOS 7.6, a better test would be to verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership, which targets carry several tenant-specific tagged networks over a shared physical uplink rather than the alternative diagnostic “Apply supported port-security policy to a shared port”.
B:The proposed check concerns “Use per-tenant route tables through VDOM separation” rather than “Share one FortiSwitch port between VDOM VLANs”: virtual-domain routing contexts can have distinct defaults and destination networks on the same FortiGate. For “Share one FortiSwitch port between VDOM VLANs” on a switch linked to a FortiGate running FortiOS 7.6, a better test would be to verify each carried VLAN maps to the intended VDOM rather than assuming port-wide ownership, which targets carry several tenant-specific tagged networks over a shared physical uplink rather than the alternative diagnostic “Use per-tenant route tables through VDOM separation”.
C:This check is suited to “Apply tenant-specific firewall policies in each VDOM” when trying to prevent one client's security rule changes from altering another client's traffic, not to verify “Share one FortiSwitch port between VDOM VLANs” at the training center. Checking “Share one FortiSwitch port between VDOM VLANs” at the training center requires evidence of its own mechanism: a shared port can transport VLAN interfaces that belong to different FortiGate VDOMs; that is not the outcome measured by “Apply tenant-specific firewall policies in each VDOM”.
D:This check is suited to “Keep FortiLink management ownership separate from tenant traffic” when trying to prevent tenant data VDOM changes from unintentionally severing switch-controller access, not to verify “Share one FortiSwitch port between VDOM VLANs” at the training center. Checking “Share one FortiSwitch port between VDOM VLANs” at the training center requires evidence of its own mechanism: a shared port can transport VLAN interfaces that belong to different FortiGate VDOMs; that is not the outcome measured by “Keep FortiLink management ownership separate from tenant traffic”.
Question 420
At the lab, a technician is choosing between several switching features to keep clients' Layer 2 segments identifiable over shared hardware. Which one belongs in the implementation plan?
- Map an inter-switch trunk to multiple VDOM VLANs
- Dedicate a managed switch port to one VDOM
- Use shared-port supported PoE settings
- Configure distinct tenant VLAN IDs on an uplink
Explanation
Correct Answer
D:At this network boundary, separate 802.1Q IDs carry tenant VLAN membership over a common permitted switch connection. The operator can test this claim by the specific check: capture tags on the shared uplink and match them to the tenants' configured VLANs.
Incorrect Answers
A:Compared with the requested “Configure distinct tenant VLAN IDs on an uplink” at the lab, this would carry separate customer networks across distribution without collapsing them into one tenant instead: the trunk transports allowed VLAN IDs while their FortiGate interfaces retain separate VDOM associations. At the lab, the operational proof would instead be to capture tags on the shared uplink and match them to the tenants' configured VLANs, whereas “Map an inter-switch trunk to multiple VDOM VLANs” is validated by a different test: inspect VLAN-to-VDOM ownership and tag preservation over both trunk endpoints.
B:For the lab, “Dedicate a managed switch port to one VDOM” is a different type of control from “Configure distinct tenant VLAN IDs on an uplink”: port-to-VDOM mapping places that port's associated network into the intended tenant context. Unlike the requested feature, that setting addresses the need to assign an endpoint-facing physical interface to a single tenant, not the objective to keep clients' Layer 2 segments identifiable over shared hardware.
C:Compared with the requested “Configure distinct tenant VLAN IDs on an uplink” at the lab, this would serve an Ethernet-powered device on a shared physical port where the model supports it instead: selected physical port properties such as PoE may be configured even when VLAN interfaces span VDOMs. At the lab, the operational proof would instead be to capture tags on the shared uplink and match them to the tenants' configured VLANs, whereas “Use shared-port supported PoE settings” is validated by a different test: check the exact hardware feature support and effective PoE behavior on that port.